Introduction
The main goals of using redundant
arrays of inexpensive disks (RAID) are to improve disk data performance and
provide data redundancy.
RAID can be handled either by the
operating system software or it may be implemented via a purpose built RAID
disk controller card without having to configure the operating system at all.
This chapter will explain how to configure the software RAID schemes supported
by RedHat/Fedora Linux.
For the sake of simplicity, the
chapter focuses on using RAID for partitions that include neither the /boot or
the root (/) filesystems.
Whether hardware- or software-based,
RAID can be configured using a variety of standards. Take a look at the most
popular.
In the Linear RAID, the RAID
controller views the RAID set as a chain of disks. Data is written to the next
device in the chain only after the previous one is filled.
The aim of Linear RAID is to
accommodate large filesystems spread over multiple devices with no data
redundancy. A drive failure will corrupt your data.
Linear mode RAID is not supported by
Fedora Linux.
With RAID 0, the RAID controller
tries to evenly distribute data across all disks in the RAID set.
Envision a disk as if it were a
plate, and think of the data as a cake. You have four cakes- chocolate,
vanilla, cherry and strawberry-and four plates. The initialization process of
RAID 0, divides the cakes and distributes the slices across all the plates. The
RAID 0 drivers make the operating system feel that the cakes are intact and
placed on one large plate. For example, four 9GB hard disks configured in a
RAID 0 set are seen by the operating system to be one 36GB disk.
Like Linear RAID, RAID 0 aims to
accommodate large filesystems spread over multiple devices with no data
redundancy. The advantage of RAID 0 is data access speed. A file that is spread
over four disks can be read four times as fast. You should also be aware that
RAID 0 is often called striping.
RAID 0 can accommodate disks of
unequal sizes. When RAID runs out of striping space on the smallest device, it
then continues the striping using the available space on the remaining drives.
When this occurs, the data access speed is lower for this portion of data,
because the total number of RAID drives available is reduced. For this reason,
RAID 0 is best used with drives of equal size.
RAID 0 is supported by Fedora Linux.
Figure 26.1 illustrates the data allocation process in RAID 0.
With RAID 1, data is cloned on a
duplicate disk. This RAID method is therefore frequently called disk mirroring.
Think of telling two people the same story so that if one forgets some of the
details you can ask the other one to remind you.
When one of the disks in the RAID
set fails, the other one continues to function. When the failed disk is
replaced, the data is automatically cloned to the new disk from the surviving
disk. RAID 1 also offers the possibility of using a hot standby spare disk that
will be automatically cloned in the event of a disk failure on any of the
primary RAID devices.
RAID 1 offers data redundancy,
without the speed advantages of RAID 0. A disadvantage of software-based RAID 1
is that the server has to send data twice to be written to each of the mirror
disks. This can saturate data busses and CPU use. With a hardware-based
solution, the server CPU sends the data to the RAID disk controller once, and
the disk controller then duplicates the data to the mirror disks. This makes
RAID-capable disk controllers the preferred solution when implementing RAID 1.
A limitation of RAID 1 is that the
total RAID size in gigabytes is equal to that of the smallest disk in the RAID
set. Unlike RAID 0, the extra space on the larger device isn't used.
RAID 1 is supported by Fedora Linux.
Figure 26.1 illustrates the data allocation process in RAID 1.
RAID 4 operates likes RAID 0 but
inserts a special error-correcting or parity chunk on an additional disk
dedicated to this purpose.
RAID 4 requires at least three disks
in the RAID set and can survive the loss of a single drive only. When this
occurs, the data in it can be recreated on the fly with the aid of the
information on the RAID set's parity disk. When the failed disk is replaced, it
is repopulated with the lost data with the help of the parity disk's
information.
RAID 4 combines the high speed provided
of RAID 0 with the redundancy of RAID 1. Its major disadvantage is that the
data is striped, but the parity information is not. In other words, any data
written to any section of the data portion of the RAID set must be followed by
an update of the parity disk. The parity disk can therefore act as a
bottleneck. For this reason, RAID 4 isn't used very frequently.
RAID 4 is not supported by Fedora
Linux.
RAID 5 improves on RAID 4 by
striping the parity data between all the disks in the RAID set. This avoids the
parity disk bottleneck, while maintaining many of the speed features of RAID 0
and the redundancy of RAID 1. Like RAID 4, RAID 5 can survive the loss of a
single disk only.
RAID 5 is supported by Fedora Linux.
Figure 26.2 illustrates the data allocation process in RAID 5.
Linux RAID 5 requires a minimum of
three disks or partitions.
Before You Start
Specially built hardware-based RAID
disk controllers are available for both IDE and SCSI drives. They usually have
their own BIOS, so you can configure them right after your system's the power
on self test (POST). Hardware-based RAID is transparent to your operating
system; the hardware does all the work.
If hardware RAID isn't available,
then you should be aware of these basic guidelines to follow when setting up
software RAID.
To save costs, many small business
systems will probably use IDE disks, but they do have some limitations.
- The total length of an IDE cable can be only a few feet long, which generally limits IDE drives to small home systems.
- IDE drives do not hot swap. You cannot replace them while your system is running.
- Only two devices can be attached per controller.
- The performance of the IDE bus can be degraded by the presence of a second device on the cable.
- The failure of one drive on an IDE bus often causes the malfunctioning of the second device. This can be fatal if you have two IDE drives of the same RAID set attached to the same cable.
For these reasons, I recommend you
use only one IDE drive per controller when using RAID, especially in a
corporate environment. In a home or SOHO setting, IDE-based software RAID may
be adequate.
Serial ATA type drives are rapidly
replacing IDE, or Ultra ATA, drives as the preferred entry level disk storage
option because of a number of advantages:
- The drive data cable can be as long as 1 meter in length versus IDE's 18 inches.
- Serial ATA has better error checking than IDE.
- There is only one drive per cable which makes hot swapping, or the capability to replace components while the system is still running, possible without the fear of affecting other devices on the data cable.
- There are no jumpers to set on Serial ATA drives to make it a master or slave which makes them simpler to configure.
- IDE drives have a 133Mbytes/s data rate whereas the Serial ATA specification starts at 150 Mbytes/sec with a goal of reaching 600 Mbytes/s over the expected ten year life of the specification.
If you can't afford more expensive
and faster SCSI drives, Serial ATA would be the preferred device for software
and hardware RAID
SCSI hard disks have a number of features
that make them more attractive for RAID use than either IDE or Serial ATA
drives.
- SCSI controllers are more tolerant of disk failures. The failure of a single drive is less likely to disrupt the remaining drives on the bus.
- SCSI cables can be up to 25 meters long, making them suitable for data center applications.
- Much more than two devices may be connected to a SCSI cable bus. It can accommodate 7 (single-ended SCSI) or 15 (all other SCSI types) devices.
- Some models of SCSI devices support "hot swapping" which allows you to replace them while the system is running.
- SCSI currently supports data rates of up to 640 Mbytes/s making them highly desirable for installations where rapid data access is imperative.
SCSI drives tend to be more
expensive than IDE drives, however, which may make them less attractive for
home use.
It is generally a not a good idea to
share RAID-configured partitions with non-RAID partitions. The reason for this
is obvious: A disk failure could still incapacitate a system.
If you decide to use RAID, all the
partitions on each RAID disk should be part of a RAID set. Many people simplify
this problem by filling each disk of a RAID set with only one partition.
Software RAID creates the equivalent
of a single RAID virtual disk drive made up of all the underlying regular
partitions used to create it. You have to format this new RAID device before
your Linux system can store files on it. Formatting, however, causes all the
old data on the underlying RAID partitions to be lost. It is best to backup the
data on these and any other partitions on the disk drive on which you want
implement RAID. A mistake could unintentionally corrupt valid data.
As you will be modifying the disk
structure of your system, you should also consider configuring RAID while your
system is running in single-user mode from the VGA console. This makes sure
that most applications and networking are shutdown and that no other users can
access the system, reducing the risk of data corruption during the exercise.
[root@bigboy
tmp]# init 1
Once finished, issue the exit
command, and your system will boot in the default runlevel provided in the
/etc/inittab file.
Configuring RAID using Fedora Linux
requires a number of steps that need to be followed carefully. In the tutorial
example, you'll be configuring RAID 5 using a system with three pre-partitioned
hard disks. The partitions to be used are:
/dev/hde1
/dev/hdf2
/dev/hdg1
Be sure to adapt the various stages
outlined below to your particular environment.
You first need to identify two or
more partitions, each on a separate disk. If you are doing RAID 0 or RAID 5,
the partitions should be of approximately the same size, as in this scenario.
RAID limits the extent of data access on each partition to an area no larger
than that of the smallest partition in the RAID set.
First use the fdisk -l command to
view all the mounted and unmounted filesystems available on your system. You
may then also want to use the df -k command, which shows only mounted
filesystems but has the big advantage of giving you the mount points too.
These two commands should help you
to easily identify the partitions you want to use. Here is some sample output
of these commands.
[root@bigboy
tmp]# fdisk -l
Disk
/dev/hda: 12.0 GB, 12072517632 bytes
255
heads, 63 sectors/track, 1467 cylinders
Units
= cylinders of 16065 * 512 = 8225280 bytes
Device Boot Start
End Blocks Id
System
/dev/hda1 *
1 13 104391
83 Linux
/dev/hda2 14 144
1052257+ 83 Linux
/dev/hda3 145 209
522112+ 82 Linux swap
/dev/hda4 210 1467
10104885 5 Extended
/dev/hda5 210 655
3582463+ 83 Linux
...
...
/dev/hda15 1455 1467
104391 83 Linux
[root@bigboy
tmp]#
[root@bigboy
tmp]# df -k
Filesystem 1K-blocks Used Available Use% Mounted on
/dev/hda2 1035692 163916
819164 17% /
/dev/hda1 101086 8357
87510 9% /boot
/dev/hda15 101086 4127
91740 5% /data1
...
...
...
/dev/hda7 5336664 464228
4601344 10% /var
[root@bigboy
tmp]#
You don't want anyone else accessing
these partitions while you are creating the RAID set, so you need to make sure
they are unmounted.
[root@bigboy
tmp]# umount /dev/hde1
[root@bigboy
tmp]# umount /dev/hdf2
[root@bigboy
tmp]# umount /dev/hdg1
You have to change each partition in
the RAID set to be of type FD (Linux raid autodetect), and you can do this with
fdisk. Here is an example using /dev/hde1.
[root@bigboy
tmp]# fdisk /dev/hde
The
number of cylinders for this disk is set to 8355.
There
is nothing wrong with that, but this is larger than 1024,
and
could in certain setups cause problems with:
1)
software that runs at boot time (e.g., old versions of LILO)
2)
booting and partitioning software from other OSs
(e.g., DOS FDISK, OS/2 FDISK)
Command
(m for help):
Now use the fdisk m command to get
some help:
Command
(m for help): m
...
...
p
print the partition table
q
quit without saving changes
s
create a new empty Sun disklabel
t
change a partition's system id
...
...
Command
(m for help):
Partition /dev/hde1 is the first
partition on disk /dev/hde. Modify its type using the t command, and specify
the partition number and type code. You also should use the L command to get a
full listing of ID types in case you forget. In this case, RAID uses type fd,
it may be different for your version of Linux.
Command
(m for help): t
Partition
number (1-5): 1
Hex
code (type L to list codes): L
...
...
...
16 Hidden FAT16 61
SpeedStor f2 DOS secondary
17 Hidden HPFS/NTF 63 GNU HURD or Sys fd Linux raid auto
18 AST SmartSleep 64
Novell Netware fe LANstep
1b Hidden Win95 FA 65 Novell Netware ff BBT
Hex
code (type L to list codes): fd
Changed
system type of partition 1 to fd (Linux raid autodetect)
Command
(m for help):
Use the p command to get the new
proposed partition table:
Command
(m for help): p
Disk
/dev/hde: 4311 MB, 4311982080 bytes
16
heads, 63 sectors/track, 8355 cylinders
Units
= cylinders of 1008 * 512 = 516096 bytes
Device Boot Start
End Blocks Id
System
/dev/hde1 1
4088 2060320+ fd
Linux raid autodetect
/dev/hde2 4089 5713
819000 83 Linux
/dev/hde4 6608 8355
880992 5 Extended
/dev/hde5 6608 7500
450040+ 83 Linux
/dev/hde6 7501 8355 430888+
83 Linux
Command
(m for help):
Use the w command to permanently
save the changes to disk /dev/hde:
Command
(m for help): w
The
partition table has been altered!
Calling
ioctl() to re-read partition table.
WARNING:
Re-reading the partition table failed with error 16: Device or resource busy.
The
kernel still uses the old table.
The
new table will be used at the next reboot.
Syncing
disks.
[root@bigboy
tmp]#
The error above will occur if any of
the other partitions on the disk is mounted.
For the sake of brevity, I won't
show the process for the other partitions. It's enough to know that the steps
for changing the IDs for /dev/hdf2 and /dev/hdg1 are very similar.
Now that the partitions have been
prepared, we have to merge them into a new RAID partition that we'll then have
to format and mount. Here's how it's done.
You use the mdadm command with the
--create option to create the RAID set. In this example we use the --level
option to specify RAID 5, and the --raid-devices option to define the number of
partitions to use.
[root@bigboy
tmp]# mdadm --create --verbose /dev/md0 --level=5 \
--raid-devices=3 /dev/hde1 /dev/hdf2
/dev/hdg1
mdadm:
layout defaults to left-symmetric
mdadm:
chunk size defaults to 64K
mdadm:
/dev/hde1 appears to contain an ext2fs file system
size=48160K
mtime=Sat Jan 27 23:11:39 2007
mdadm:
/dev/hdf2 appears to contain an ext2fs file system
size=48160K
mtime=Sat Jan 27 23:11:39 2007
mdadm:
/dev/hdg1 appears to contain an ext2fs file system
size=48160K
mtime=Sat Jan 27 23:11:39 2007
mdadm:
size set to 48064K
Continue
creating array? y
mdadm:
array /dev/md0 started.
[root@bigboy
tmp]#
The /proc/mdstat file provides the
current status of all RAID devices. Confirm that the initialization is finished
by inspecting the file and making sure that there are no initialization related
messages. If there are, then wait until there are none.
[root@bigboy
tmp]# cat /proc/mdstat
Personalities :
[raid5]
read_ahead
1024 sectors
md0 :
active raid5 hdg1[2] hde1[1] hdf2[0]
4120448 blocks level 5, 32k chunk,
algorithm 3 [3/3] [UUU]
unused
devices:
[root@bigboy
tmp]#
Notice that the new RAID device is
called /dev/md0. This information will be required for the next step.
Your new RAID partition now has to
be formatted. The mkfs.ext3 command is used to do this.
[root@bigboy
tmp]# mkfs.ext3 /dev/md0
mke2fs
1.39 (29-May-2006)
Filesystem
label=
OS
type: Linux
Block
size=1024 (log=0)
Fragment
size=1024 (log=0)
36144
inodes, 144192 blocks
7209
blocks (5.00%) reserved for the super user
First
data block=1
Maximum
filesystem blocks=67371008
18
block groups
8192
blocks per group, 8192 fragments per group
2008
inodes per group
Superblock
backups stored on blocks:
8193, 24577, 40961, 57345, 73729
Writing
inode tables: done
Creating
journal (4096 blocks): done
Writing
superblocks and filesystem accounting information: done
This
filesystem will be automatically checked every 33 mounts or
180
days, whichever comes first. Use tune2fs
-c or -i to override.
[root@bigboy
tmp]#
Your system doesn't automatically
remember all the component partitions of your RAID set. This information has to
be kept in the mdadm.conf file. The formatting can be tricky, but fortunately
the output of the mdadm --detail --scan --verbose command provides you with it.
Here we see the output sent to the screen.
[root@bigboy
tmp]# mdadm --detail --scan --verbose
ARRAY
/dev/md0 level=raid5 num-devices=4
UUID=77b695c4:32e5dd46:63dd7d16:17696e09
devices=/dev/hde1,/dev/hdf2,/dev/hdg1
[root@bigboy
tmp]#
Here we export the screen output to
create the configuration file.
[root@bigboy
tmp]# mdadm --detail --scan --verbose > /etc/mdadm.conf
The next step is to create a mount
point for /dev/md0. In this case we'll create one called /mnt/raid
[root@bigboy
mnt]# mkdir /mnt/raid
The /etc/fstab file lists all the
partitions that need to mount when the system boots. Add an Entry for the RAID
set, the /dev/md0 device.
/dev/md0 /mnt/raid ext3
defaults 1 2
Do not use labels in the /etc/fstab
file for RAID devices; just use the real device name, such as /dev/md0. In
older Linux versions, the /etc/rc.d/rc.sysinit script would check the
/etc/fstab file for device entries that matched RAID set names listed in the
now unused /etc/raidtab configuration file. The script would not automatically
start the RAID set driver for the RAID set if it didn't find a match. Device
mounting would then occur later on in the boot process. Mounting a RAID device
that doesn't have a loaded driver can corrupt your data and produce this error.
Starting
up RAID devices: md0(skipped)
Checking
filesystems
/raiddata:
Superblock has a bad ext3 journal(inode8)
CLEARED.
***journal
has been deleted - file system is now ext 2 only***
/raiddata:
The filesystem size (according to the superblock) is 2688072 blocks.
The
physical size of the device is 8960245 blocks.
Either
the superblock or the partition table is likely to be corrupt!
/boot:
clean, 41/26104 files, 12755/104391 blocks
/raiddata:
UNEXPECTED INCONSISTENCY; Run fsck manually (ie without -a or -p options).
If you are not familiar with the /etc/fstab
file use the man fstab command to get a comprehensive explanation of each data
column it contains.
The /dev/hde1, /dev/hdf2, and
/dev/hdg1 partitions were replaced by the combined /dev/md0 partition. You
therefore don't want the old partitions to be mounted again. Make sure that all
references to them in this file are commented with a # at the beginning of the
line or deleted entirely.
#/dev/hde1 /data1 ext3
defaults 1 2
#/dev/hdf2 /data2 ext3
defaults 1 2
#/dev/hdg1 /data3 ext3
defaults 1 2
Use the mount command to mount the
RAID set. You have your choice of methods:
- The mount command's -a flag causes Linux to mount all the devices in the /etc/fstab file that have automounting enabled (default) and that are also not already mounted.
[root@bigboy
tmp]# mount -a
- You can also mount the device manually.
[root@bigboy
tmp]# mount /dev/md0 /mnt/raid
The /proc/mdstat file provides the
current status of all the devices.
[root@bigboy
tmp]# raidstart /dev/md0
[root@bigboy
tmp]# cat /proc/mdstat
Personalities :
[raid5]
read_ahead
1024 sectors
md0 :
active raid5 hdg1[2] hde1[1] hdf2[0]
4120448 blocks level 5, 32k chunk,
algorithm 3 [3/3] [UUU]
unused
devices:
[root@bigboy
tmp]#
Linux software RAID provides
redundancy across partitions and hard disks, but it tends to be slower and less
reliable than RAID provided by a hardware-based RAID disk controller.
Hardware RAID configuration is
usually done via the system BIOS when the server boots up, and once configured,
it is absolutely transparent to Linux. Unlike software RAID, hardware RAID
requires entire disks to be dedicated to the purpose and when combined with the
fact that it usually requires faster SCSI hard disks and an additional
controller card, it tends to be expensive.
Remember to take these factors into
consideration when determining the right solution for your needs and research
the topic thoroughly before proceeding. Weighing cost versus reliability is
always a difficult choice in systems administration.